Meanwhile, testing and commissioning practices largely still focus on individual relays, not the protective relaying system. Should evidence of overheating be found, the insulation should be checked for embrittlement and, where necessary, replaced. It allows investigations into protection of transformers, autotransformers, generators and other electrical apparatus with two windings. This paper concerns with modeling and testing of a digital differential relay with a single slope characteristic, dedicated for power transformers protection, using matlabsimulink. Commission testing methods for protection systems mipsycon. The secondaries of all cts and differential relay form a closed loop. Faults instrument transformers correlation to drawings other. Busbar protection busbar differential protection scheme. Applying sel differential relays introduction to transformer differential protection explain challenges of transformer differential protection understand need for tap, phase, and zerosequence compensation and how they work. Aug 31, 2018 in voltage differential busbar protection the cts of all incoming and outgoing feeders are connected in series instead of connecting them in parallel. This relay testing book is our core handbook and is used by large organizations across north america in their training programs.
Differential protection for standard power transformers has been used for decades. Within the limits of the accuracy of the cts and the relays, true bus differential relaying will detect all faults on the protected bus. It provides a basic introduction to endtoend testing along with clear, stepbystep procedures to apply in the field, including. True bus differential relaying compares all currents entering and leaving a switchgear bus. Thus, it can be quite tricky to test a numerical transformer differential relay by secondary injection in order to verify that the relay is set properly to protect transformer in a particular application. Differential protection is based on kirchhoffs laws, stating that all current into a network node shall add up to 0 in an ideal system. The faults occur in the transformer inside the insulating oil can be detected by buchholz relay. Sel587 current differential relay schweitzer engineering. A mho relay is used for distance protection on a line, a translay relay is used for line differential protection via a pilot scheme, a merz price relay is used for generator. Test switch its2 differential protection and automation system schweitzer va.
Pdf modeling and testing of a digital differential relay. With modern numerical transformer differential relays all above compensations are provided in the relay software. Universal testing method for power transformer differential. How to test a transformer differential relay slope, high. Electrical technology and industrial practice 3,445 views. Protection relays differential relays high impedance differential relay highimpedance differential relays are typically used for bus protection. Pdf transformer differential protection relay service. Faults instrument transformers correlation to drawings. Differential protection of transformer differential relays. Generally differential protection is provided in the electrical power transformer rated more than 5mva. Testing and maintenance of protective relays always begins with a thorough visual and mechanical inspection. Jul 09, 2018 this video outlines the basic principles behind differential protection and is a sample of the full 2.
Partial differential relaying powell industries, inc. While setting parameters will differ depending on the type of current differential relay, the setting principles and system conditions to consider remain largely the same. Use single or dual differential channels for reliability. Th e use of overcurrent relays will result in comparatively. Type test certificate, transformer protection ret670 version 2. Differential relaying provides selectivity by providing a zone of protection with a circuit of interconnected cts. Current differential line protection setting considerations s. Singlezone frameearth protection it is important that the impedance between the frame and ground should not be very high, as the current carried would not be large enough to be sensed by relay. Following parameters define differential characteristics. Assuming the relay which is responsible is known further information is needed to be evaluated 1. Differential protection of a transformer the transformer is one of the major equipment in power system. Transformer differential relays haverestraint coils as indicated in figure 1. Here, relay coil of 96a and 96b are in series with differential busbar protection relay contact 87a1 and 87b1 respectively.
The transformer could serve as a stepup as well as an earthing transformer. Reactors and capacitors there are two basic types of differential protection. When testing the mbci differential relay, it is necessary to short the. Selwa05010w wiring harness for sel501 and sel587 connectorized relays, features new shorting connector. As the name suggests, one of the main functions provided by the relay is zdistance protection 21 or impedance protection. Line differential protection red670 ied belong to the relion protection and control product family. If the circuit to be tested is in service, one relay at a time should be removed if applicable so as not to totally disable the protection. Thompson, schweitzer engineering laboratories, inc. The differential relay works on the principle of comparison between the phase angle and magnitude of two or. Within the limits of the accuracy of the cts and the relays, true bus differential relaying will. It is based on ampereturnbalance of all windings mounted on the same magnetic core lag. Sep 08, 2016 general scheme of differential protection 6.
The principles of differential protection you must. Thus the relay current equals the difference of the respective magnetisation currents. Even if the scheme has been thoroughly tested in the factory, wiring to the cts and vts on site may be incorrectly carried out, or the ctsvts may have been incorrectly installed. Facilities instructions, standards, and techniques volume 38 field test procedure for protective relays internet version of this manual created july 2000 facilities engineering branch denver office denver, colorado the appearance of the internet version of this manual may differ from the original, but the contents do not. It is also an application that demands the relay be able to operate with unequal ct. Differential protection for arbitrary 3ph power transformer. However, the increased availability of digital communications channels has renewed the interest in. Excitation current from testing 150 percent overvoltage primary current a cycles 0. Apply subcycle current differential protection with included fourzone distance and directional overcurrent backup. A differential protection relay is defined as the relay that operates when the phase difference of two or more identical electrical quantities exceeds a predetermined amount. It connects to tecquipments protection and relay test set psl50 and other modules in the power system range. May 15, 2018 generally differential protection is provided in the electrical power transformer rated more than 5mva. Phase testing connections for the figure 1 transformer traditional 1. The reason for the discrepancy will not be a change in the relay characteristic but a change in the test conditions, for example, the relay s proximity to a steel cabinet.
Commissioning a test for a differential protection scheme for a threewinding transformer figure 1. The relion product family offers the widest range of products for the protection, control, measurement and supervision of power systems. For further information, please consult your local sales representative or the factory. Easy method for testing transformer differential relays. Jul 07, 2019 differential protective relay is a protective relay that functions on a percentage or phase angle or other quantitative difference of two currents. Figure 1 shows a simple differential protection scheme, also known as a merzprice scheme. Differential relay operation during transformer energization category.
Thus, the true purpose of preventative maintenance may be lost. This is the test procedure for siemens 7ut61 relay iec61850 supported numerical relay. An example is the case of transformer differential protection operating during energization due to low second harmonic current content. Easy and intuitive method for testing transformer differential relays english pdf article designing next generations protection systems english pdf article. Commissioning a test for a differential protection scheme.
Ret670 transformer protection substation automation. Not values calculated from relay settings line protection test values from sc program closein reverse fault. The differential protection of transformer has many advantages over other schemes of protection. Operation, maintenance, and field test procedures for protective relays and associated circuits iii acronyms and abbreviations a ampere ac alternating current amp ampere ansi american national standards institute bes bulk electric system carma capital asset and resource management application ccvt coupling capacitor voltage transformers co. Mho relay translay relay merz price relay buchholz relay quite honestly, none of these answers seem 100% right. Principles of differential relaying setting a low z diff relay. Omicron cmc256 or 356 test equipment or any equivalent to be used. If polarity of all cts are properly matched, the sum of voltage across all ct secondaries is zero. Directional over current relayprotection of parallel linesdirectional over current protection duration. A numerical differential protection relay presented in an educational format. Understand the basic characteristics of differential protection. For this reason transformer differential relays are said to percentage differential relays.
Advanced differential offers a set of modules for testing differentialschemes. Use the sel311l line current differential relay with integral fourzone distance backup for easytoapply, highspeed line protection. Strictly speaking the rc tells us how much current a relay will use to restrain based on the currents. The differential relay works on the principle of comparison between the phase angle and magnitude of two or more similar electrical quantities. Two different protection solutions will be given depending on which winding of the step up transformer will be considered as the main i. Thus, a new standardized testing methodology for transformer differential protection relay. Pdf easy method for testing transformer differential relays. Although nowadays differential protection is achieved numerically, in order to understand the principles of differential protection it is useful to analyze the ubiquitous electromechanical relay. An overcurrent relay 51n or a differential relay 87g gives the protection for each generator. Installation of protection relays at site creates a number of possibilities for errors in the implementation of the scheme to occur. Transformer differential relay testing and how to create slope on omicron kit for ret 620 relay. Learn the basics of differential protection of transformers. Phasetoground line distance protection testing 451. The principles of differential protection you must understand.
The removal of the connection plug in drawout relays may reveal evidence of severe fault currents or contami. Percentage restrained differential, percentage of what. Differential protection in power transformer duration. To prove the calibration of the relay, it is convenient to check each end separately, isolated from the pilots. Current differential line protection setting consideration. Since type testing of a digital or numerical relay involves testing of software as well as hardware, the type testing process is very complicated and more involved than a static or electromechanical relay. But if any fault occurs in the transformer but not in oil then it can not be detected by buchholz relay. Pdf differential protection for standard power transformers has been used for decades. Figure 1 shows a simple differential protection scheme, also known as.
It is a static device, totally enclosed and usually oil immersed, and therefore the fault occurs on them are usually rare. Oct 02, 2016 learn the basics of differential protection of transformers. Externally earthed system with multiple generators g 87g 51n. Current balance differential protection voltage balanced differential protection 1. Sel5870, 1 connectorized current differential relay. It is a static device, totally enclosed and usually oil immersed, and. Testing numerical transformer differential relays commissioning. The remainder of this manual should be read and kept for reference to ensure maximum benefit from the 745 transformer protection system.
Understanding and testing the abb red670 distanceline differential relay 10 introduction before starting the relay distance relays 87l2167n are used in line protection and cable protection schemes. Transformer differential protection, relay testing, sequence components. The transformer needs to generate a ground current of at least 50% of generator rated current to provide about 95% or more winding coverage. Operation, maintenance, and field test procedures for. The value of the operate current has to be a certain set percentage higher than the current flowing in the restraint coils. Red670 line differential protection substation automation. Differential protective relay is a protective relay that functions on a percentage or phase angle or other quantitative difference of two currents. Protection functions bias differential protection 87 harmonic restraint protection over fluxing i. Overall differentail protection for thermal power plant.
Erwin rfl electronics inc 353 powerville road boonton twp, nj 07005 abstract the most common pilot line protection today is directional comparison by use of distance relays. The arrangement will lack earth fault protection before generator breakers are closed. To ensure interoperable and futureproof solutions, relion products have been designed to implement the. As soon as the substation was commissioned, the customer performed the primary testing of the pst protection by applying closeby primary single phase to ground faults. Bus protection is an application that demands many sets of cts be connected to the relays. Principles of differential relaying my protection guide. Review the application and ensure that it has been applied correctly. Differential protection is applicable to all parts of the power system. Principles of differential relaying the restraint characteristic what needs to be realised is that the first one is properly termed the restraint characteristic rc whilst the latter is an operating characteristic. An alternative principle for line protection that is quickly becoming the norm is differential protection. The slope characteristic provides high sensitivity when low levels of current. This relay testing book is a shorter, supplemental softcover handbook laserfocused on endtoend testing. Abstractpercentage restrained differential protection is one of the oldest forms of adaptive protection algorithms. When primary current both ends are the same, have identical turns ratios and no saturation then, i21p i21q.